Công ty Âu Châu chúng tôi phân phối các sản phẩm của Bronkhorst trên toàn quốc. Với giá cả thương lượng và dịch vụ nhanh chóng.
Liên hệ chúng tôi khi cần biết giá:
Email: sales01@eutc.com.vn
Mobile: 0919 263 967
Website: www.eutc.com.vn
Một số thiết bị Bronkhorst mà chúng tôi phân phối:
Code
|
Description
|
F-202AI-M20-AGD-44-V
|
Digital Mass Flow Meter
Model Series : IN-FLOW Select Classification : IP-65 Material : AISI 316L Fluid : AiR Range : 0.2...10 m3n/h Accuracy : ±0.5% RD plus ±0.1% FS (At calibration conditions) Inlet Pressure : 5...6 bar (g) Outlet Pressure : 1.5...2 bar (g) Valve function : Normally Closed Temperature : -10...50 °C Seals : Viton Plunger : Viton Connections : 12 mm OD compression type Output Signal : 4...20 mA sourcing (RS-232 0...100%) Setpoint : 4...20 mA sinking Supply : +15...24 Vdc |
F-201CV-20K-AGD-33-V
|
Digital Mass Flow Controller
Model Series: EL-FLOW Select Classification: IP-40 Material: AISI 316L Fluid: AiR Range: 0.4...20 ln/min Accuracy: ±0.5% RD plus ±0.1% FS Inlet Pressure: 2 bar (g) Outlet Pressure: 0 bar (g) Valve function: Normally Closed Temperature: 20 °C |
F-101EI-AGD-88-K
|
Digital Mass Flow Meter
Model Series : LOW-ΔP-FLOW Classification : IP-65 Fluid : N2 (Nitrogen) Range : 0.18...9 ln/min Accuracy : ±1% FS (At calibration conditions) Certificate : 3-point calibration Pressure : 3 bar (g) Temperature : 20 °C Seals : Kalrez Connections : 1/4" face seal male Output Signal : 4...20 mA sourcing (RS-232 0...100%) Supply : +15...24 Vdc |
F-111AI-70K-AGD-88-K
|
Digital Mass Flow Meter
Model Series : IN-FLOW Select Classification : IP-65 Fluid : N2 (Nitrogen) Range : 0.824...41.2 ln/min Accuracy : ±0.5% RD plus ±0.1% FS (At calibration conditions) Certificate : 3-point calibration Pressure : 3 bar (g) Temperature : 20 °C Seals : Kalrez Connections : 1/4" face seal male Output Signal : 4...20 mA sourcing (RS-232 0...100%) Supply : +15...24 Vdc |
F-201EI-AGD-88-K
|
Model Series : LOW-ΔP-FLOW
Classification : IP-65 Fluid : N2 (Nitrogen) Range : 0.18...9 ln/min Accuracy : ±1% FS (At calibration conditions) Certificate : 3-point calibration Inlet Pressure : 3 bar (g) Outlet Pressure : 0.2 bar (g) Orifice : Ø 1 mm Valve function : Normally Closed Temperature : 20 °C Seals : Kalrez Plunger : Kalrez Connections : 1/4" face seal male Output Signal : 4...20 mA sourcing (RS-232 0...100%) Setpoint : 4...20 mA sinking Supply : +15...24 Vdc |
F-201EI-AGD-88-Z
|
Digital Mass Flow Meter
Model Series : LOW-ΔP-FLOW Classification : IP-65 Fluid : N2 (Nitrogen) Range : 0.18...9 ln/min Accuracy : ±1% FS (At calibration conditions) Certificate : 3-point calibration Inlet Pressure : 3 bar (g) Outlet Pressure : 0.2 bar (g) Orifice : Ø 1 mm Valve function : Normally Closed Temperature : 20 °C Seals : Viton Plunger : Kalrez Connections : 1/4" face seal male Output Signal : 4...20 mA sourcing (RS-232 0...100%) Setpoint : 4...20 mA sinking Supply : +15...24 Vdc |